<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>M+S Hydraulic Archives - Hydraulics BG</title>
	<atom:link href="https://hydraulics-bg.com/product-brand/ms-hydraulic/feed/" rel="self" type="application/rss+xml" />
	<link>https://hydraulics-bg.com/product-brand/ms-hydraulic/</link>
	<description></description>
	<lastBuildDate>Mon, 06 Nov 2023 13:07:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://hydraulics-bg.com/wp-content/uploads/2023/05/favicon-100x100.png</url>
	<title>M+S Hydraulic Archives - Hydraulics BG</title>
	<link>https://hydraulics-bg.com/product-brand/ms-hydraulic/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Hydraulic motor &#8211; MSWM</title>
		<link>https://hydraulics-bg.com/hydraulics/hydraulic-motors-ms-hydraulic/disk-valve-heavy-duty/hydraulic-motor-mswm/</link>
		
		<dc:creator><![CDATA[hydraulics]]></dc:creator>
		<pubDate>Mon, 26 Jun 2023 10:14:49 +0000</pubDate>
				<guid isPermaLink="false">https://hydraulics-bg.com/?post_type=product&#038;p=9461</guid>

					<description><![CDATA[<h4>Applications:</h4>
<ul>
<li>Sawmill machines</li>
<li>Woodworking machines</li>
<li>Metal working machines</li>
<li>Agriculture machines</li>
<li>Road building machines</li>
<li>Mining machinery</li>
<li>Food industries</li>
<li>Special vehicles etc.</li>
</ul>
<h4>Options:</h4>
<ul>
<li>Model - Disk valve, roll-gerotor</li>
<li>Wheel mount</li>
<li>Side and rear ports</li>
<li>Shafts - straight, splined and tappered</li>
<li>Metric and BSPP ports</li>
<li>Other special features</li>
</ul>
<p>The post <a href="https://hydraulics-bg.com/hydraulics/hydraulic-motors-ms-hydraulic/disk-valve-heavy-duty/hydraulic-motor-mswm/">Hydraulic motor &#8211; MSWM</a> appeared first on <a href="https://hydraulics-bg.com">Hydraulics BG</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table id="hid-motors" class="table">
<tbody>
<tr class="headers">
<td rowspan="2">Code</td>
<td rowspan="2">Displacement</p>
<p>[cm<sup>3</sup>/rev]</td>
<td colspan="2">Max. speed</p>
<p>[RPM]</td>
<td colspan="2">Max. Torgue</p>
<p>[daNm]</td>
<td colspan="2">Max. Output</p>
<p>[kW]</td>
<td colspan="2">Max. Pressure Drop</p>
<p>[bar]</td>
<td colspan="2">Max. Oil Flow</p>
<p>[Ipm]</td>
</tr>
<tr class="remarks">
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
</tr>
<tr class="alt">
<td class="code">MSWM 160</td>
<td class="displ">159,7</td>
<td class="speed">470</td>
<td class="speed">560</td>
<td class="torg-cont">46</td>
<td class="torg-int">51,5</td>
<td class="out-cont">18,6</td>
<td class="out-int">24</td>
<td class="press-cont">200</td>
<td class="press-int">225</td>
<td class="flow">75</td>
<td class="flow">90</td>
</tr>
<tr>
<td class="code">MSWM 200</td>
<td>200</td>
<td>375</td>
<td>450</td>
<td>56,6</td>
<td>64,5</td>
<td>18,1</td>
<td>24</td>
<td>200</td>
<td>225</td>
<td>75</td>
<td>90</td>
</tr>
<tr class="alt">
<td class="code">MSWM 250</td>
<td>250</td>
<td>300</td>
<td>360</td>
<td>70,8</td>
<td>80,6</td>
<td>18</td>
<td>23,8</td>
<td>200</td>
<td>225</td>
<td>75</td>
<td>90</td>
</tr>
<tr>
<td class="code">MSWM 315</td>
<td>314,9</td>
<td>240</td>
<td>285</td>
<td>90</td>
<td>90,6</td>
<td>17</td>
<td>20,2</td>
<td>200</td>
<td>220</td>
<td>75</td>
<td>90</td>
</tr>
<tr class="alt">
<td class="code">MSWM 400</td>
<td>397</td>
<td>185</td>
<td>225</td>
<td>90</td>
<td>97</td>
<td>11</td>
<td>12</td>
<td>160</td>
<td>175</td>
<td>75</td>
<td>90</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://hydraulics-bg.com/hydraulics/hydraulic-motors-ms-hydraulic/disk-valve-heavy-duty/hydraulic-motor-mswm/">Hydraulic motor &#8211; MSWM</a> appeared first on <a href="https://hydraulics-bg.com">Hydraulics BG</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydraulic pumps – PAP 22÷28</title>
		<link>https://hydraulics-bg.com/hydraulics/hydraulic-pumps/axial-piston-pumps/hydraulic-motors-pap-22%c3%b728/</link>
		
		<dc:creator><![CDATA[lenabg]]></dc:creator>
		<pubDate>Mon, 12 Jun 2023 12:35:30 +0000</pubDate>
				<guid isPermaLink="false">https://hydraulics-bg.com/?post_type=product&#038;p=9286</guid>

					<description><![CDATA[<div class="col-lg-6">
<h4>Applications:</h4>
<ul>
<li>Open loop circuit</li>
<li>Agricultural machines</li>
<li>Road building machines</li>
<li>Mining machinery</li>
<li>Food industry machines</li>
<li>Special vehicles</li>
</ul>
</div>
<div class="col-lg-6">
<h4>Options:</h4>
<ul>
<li>Port options</li>
<li>Shaft options</li>
<li>High pressure ports</li>
</ul>
</div>
<div class="col-lg-6">
<h4>Advantages:</h4>
<ul>
<li>Low noise</li>
<li>Low pulsation</li>
<li>Long service life</li>
<li>High power density</li>
</ul>
</div>
<p>The post <a href="https://hydraulics-bg.com/hydraulics/hydraulic-pumps/axial-piston-pumps/hydraulic-motors-pap-22%c3%b728/">Hydraulic pumps – PAP 22÷28</a> appeared first on <a href="https://hydraulics-bg.com">Hydraulics BG</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul>
<li class="even typeTextarea group11"><span class="itemExtraFieldsLabel">Parameters:</span>
<div class="table-responsive">
<table id="hid-motors" class="table">
<tbody>
<tr class="headers">
<td rowspan="2">Code</td>
<td rowspan="2">Displacement</p>
<p>cm<sup>3</sup>/rev [in<sup>3</sup>/rev]</td>
<td colspan="2">Max. Driving Speed</p>
<p>RPM</td>
<td colspan="2">Max. Driving Torgue***</p>
<p>Nm [lb-in]</td>
<td colspan="2">Output</p>
<p>kW [HP]</td>
<td colspan="2">Max. Pressure</p>
<p>bar [PSI]</td>
<td colspan="2">Max. Oil Flow</p>
<p>Ipm [GPM]</td>
</tr>
<tr class="remarks">
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int**</td>
<td>cont.</td>
<td>int**</td>
<td>cont.</td>
<td>int**</td>
<td>cont.</td>
<td>int*</td>
</tr>
<tr class="alt">
<td class="code map">PAP 22</td>
<td class="displ map">22,15 [1.35]</td>
<td class="speed">3000</td>
<td class="speed">3400</td>
<td class="torg-cont map">123 [1090]</td>
<td class="torg-int map">148 [1310]</td>
<td class="out-cont">30 [40.2]</td>
<td class="out-int">35 [47]</td>
<td class="press-cont">350 [5080]</td>
<td class="press-int">420 [6100]</td>
<td class="flow">64 [16.9]</td>
<td class="flow">82 [21.7]</td>
</tr>
<tr>
<td class="code">PAP 28</td>
<td>28,47 [1.74]</td>
<td>3000</td>
<td>3400</td>
<td>158 [1400]</td>
<td>190 [1680]</td>
<td>38 [51]</td>
<td>48 [64.4]</td>
<td>350 [5080]</td>
<td>420 [6100]</td>
<td>70 [18.5]</td>
<td>90 [23.8]</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>* <em>Intermitten speed (flow) is for pressure up to 150 [2200] bar [PSI]</em><br />
** <em>Intermitten load: the permissible values may occur for max. 10% of product lifetime.</em><br />
*** <em>Theoretical torque</em></li>
<li class="odd typeTextarea group11"><span class="itemExtraFieldsLabel">General:</span>
<div class="table-responsive">
<table class="table prodSpec">
<tbody>
<tr class="even">
<td>Min Speed</td>
<td>RPM</td>
<td class="vals">500</td>
</tr>
<tr class="odd">
<td>Max Pressure in Drain Line</td>
<td>bar [psi]</td>
<td class="vals">5 [70]</td>
</tr>
<tr class="even">
<td>Pressure fluid</td>
<td></td>
<td class="vals">Mineral based- HLP(DIN 51524) or HM(ISO 6743/4)</td>
</tr>
<tr class="odd">
<td>Temperature range,</td>
<td>°C [°F]</td>
<td class="vals">-40÷82 [-40÷180]</td>
</tr>
<tr class="even">
<td>Optimal Viscosity range,</td>
<td>mm<sup>2</sup>/s [SUS]</td>
<td class="vals">12÷68 [70÷320]</td>
</tr>
<tr class="odd">
<td>Filtration</td>
<td></td>
<td class="vals">ISO code 18/16/13 (Min. recommended fluid filtration of 10 micron )</td>
</tr>
</tbody>
</table>
</div>
</li>
</ul>
<p>The post <a href="https://hydraulics-bg.com/hydraulics/hydraulic-pumps/axial-piston-pumps/hydraulic-motors-pap-22%c3%b728/">Hydraulic pumps – PAP 22÷28</a> appeared first on <a href="https://hydraulics-bg.com">Hydraulics BG</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hydraulic Motor MP 25, MP 32, MP 40, MP 50, MP 100, MP 125, MP 160, MP 200, MP 160, MP 250, MP 315, MP 400, MP 500, MP 630</title>
		<link>https://hydraulics-bg.com/hydraulics/hydraulic-motors-ms-hydraulic/hydraulic-motors-ms-spool-valve/hydraulic-motor-mp-160-mp-200-mp-160-mp-250-mp-315-mp-400-mp-500-mp-630/</link>
		
		<dc:creator><![CDATA[lenabg]]></dc:creator>
		<pubDate>Wed, 07 Jun 2023 13:40:23 +0000</pubDate>
				<guid isPermaLink="false">https://hydraulics-bg.com/?post_type=product&#038;p=9194</guid>

					<description><![CDATA[<p>Applications:</p>
<ul>
<li>Conveyors</li>
<li>Feeding mechanism of robots and manipulators</li>
<li>Metal working machines</li>
<li>Textile machines</li>
<li>Agricultural machines</li>
<li>Food industries</li>
<li>Grass cutting machinery etc.</li>
</ul>
<p>Options:</p>
<ul>
<li>Model - Spool valve, gerotor</li>
<li>Flange and wheel mount</li>
<li>Motor with needle bearing</li>
<li>Side and rear ports</li>
<li>Shafts - straight, splined and tapered</li>
<li>Shaft seal for high and low pressure</li>
<li>Metric and BSPP ports</li>
<li>Speed sensoring</li>
<li>Other special features</li>
</ul>
<p>The post <a href="https://hydraulics-bg.com/hydraulics/hydraulic-motors-ms-hydraulic/hydraulic-motors-ms-spool-valve/hydraulic-motor-mp-160-mp-200-mp-160-mp-250-mp-315-mp-400-mp-500-mp-630/">Hydraulic Motor MP 25, MP 32, MP 40, MP 50, MP 100, MP 125, MP 160, MP 200, MP 160, MP 250, MP 315, MP 400, MP 500, MP 630</a> appeared first on <a href="https://hydraulics-bg.com">Hydraulics BG</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul>
<li class="even typeTextarea group3"><span class="itemExtraFieldsLabel">Parameters:</span>
<div class="table-responsive">
<table id="hid-motors" class="table">
<tbody>
<tr class="headers">
<td rowspan="2">Code</td>
<td rowspan="2">Displacement</p>
<p>[cm<sup>3</sup>/rev]</td>
<td colspan="2">Max. speed</p>
<p>[RPM]</td>
<td colspan="2">Max. Torgue</p>
<p>[daNm]</td>
<td colspan="2">Max. Output</p>
<p>[kW]</td>
<td colspan="2">Max. Pressure Drop</p>
<p>[bar]</td>
<td colspan="2">Max. Oil Flow</p>
<p>[Ipm]</td>
</tr>
<tr class="remarks">
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
<td>cont.</td>
<td>int*</td>
</tr>
<tr class="alt">
<td class="code">MP 25</td>
<td class="displ">25</td>
<td class="speed">1600</td>
<td class="speed">1815</td>
<td class="torg-cont">3,3</td>
<td class="torg-int">4,7</td>
<td class="out-cont">4,5</td>
<td class="out-int">6,1</td>
<td class="press-cont">100</td>
<td class="press-int">140</td>
<td class="flow">40</td>
<td class="flow">45</td>
</tr>
<tr>
<td class="code">MP 32</td>
<td>32</td>
<td>1560</td>
<td>1720</td>
<td>4,3</td>
<td>6,1</td>
<td>5,8</td>
<td>7,8</td>
<td>100</td>
<td>140</td>
<td>50</td>
<td>55</td>
</tr>
<tr>
<td class="code">MP 40</td>
<td>40</td>
<td>1500</td>
<td>1750</td>
<td>6,2</td>
<td>8,2</td>
<td>8,4</td>
<td>11,6</td>
<td>120</td>
<td>155</td>
<td>60</td>
<td>70</td>
</tr>
<tr>
<td class="code">MP 50</td>
<td>49,5</td>
<td>1210</td>
<td>1515</td>
<td>9,4</td>
<td>11,9</td>
<td>10,1</td>
<td>12,2</td>
<td>140</td>
<td>175</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td class="code">MP 80</td>
<td>79,2</td>
<td>755</td>
<td>945</td>
<td>15,1</td>
<td>19,5</td>
<td>10,2</td>
<td>12,5</td>
<td>140</td>
<td>175</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td class="code">MP 100</td>
<td>99</td>
<td>605</td>
<td>755</td>
<td>19,3</td>
<td>23,7</td>
<td>10,5</td>
<td>12,8</td>
<td>140</td>
<td>175</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td class="code">MP 125</td>
<td>123,8</td>
<td>486</td>
<td>605</td>
<td>23,7</td>
<td>29,8</td>
<td>10,2</td>
<td>12</td>
<td>140</td>
<td>175</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td class="code">MP 160</td>
<td>158,4</td>
<td>378</td>
<td>472</td>
<td>31,3</td>
<td>37,8</td>
<td>10,1</td>
<td>12,1</td>
<td>140</td>
<td>175</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td class="code">MP 200</td>
<td>198</td>
<td>303</td>
<td>378</td>
<td>36,6</td>
<td>45,6</td>
<td>10</td>
<td>12</td>
<td>140</td>
<td>175</td>
<td>60</td>
<td>75</td>
</tr>
<tr class="alt">
<td class="code">MP 250</td>
<td>247,5</td>
<td>242</td>
<td>303</td>
<td>38</td>
<td>58,3</td>
<td>7,5</td>
<td>12</td>
<td>110</td>
<td>175</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td class="code">MP 315</td>
<td>316,8</td>
<td>190</td>
<td>236</td>
<td>38</td>
<td>56</td>
<td>5,8</td>
<td>9</td>
<td>90</td>
<td>140</td>
<td>60</td>
<td>75</td>
</tr>
<tr class="alt">
<td class="code">MP 400</td>
<td>396</td>
<td>150</td>
<td>189</td>
<td>36</td>
<td>59</td>
<td>4,6</td>
<td>7,8</td>
<td>70</td>
<td>115</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td class="code">MP 500</td>
<td>495</td>
<td>120</td>
<td>150</td>
<td>39</td>
<td>57</td>
<td>3,5</td>
<td>7,2</td>
<td>60</td>
<td>90</td>
<td>60</td>
<td>75</td>
</tr>
<tr class="alt">
<td class="code">MP 630</td>
<td>623,6</td>
<td>95</td>
<td>120</td>
<td>44</td>
<td>64</td>
<td>3,3</td>
<td>5,6</td>
<td>55</td>
<td>80</td>
<td>60</td>
<td>75</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>* <em>Intermitten operation: the permissible values may occur for max. 10% of every minute.</em></li>
<li class="odd typeTextarea group3"><span class="itemExtraFieldsLabel">General:</span>
<div class="table-responsive">
<table class="table prodSpec">
<tbody>
<tr class="even">
<td>Pressure fluid</td>
<td></td>
<td class="vals">Mineral based- HLP(DIN 51524) or HM(ISO 6743/4)</td>
</tr>
<tr class="odd">
<td>Temperature range,</td>
<td>°C</td>
<td class="vals">-40÷140</td>
</tr>
<tr class="even">
<td>Optimal Viscosity range,</td>
<td>mm<sup>2</sup>/s</td>
<td class="vals">20÷75</td>
</tr>
<tr class="odd">
<td>Filtration</td>
<td></td>
<td class="vals">ISO code 20/16 (Min. recommended fluid filtration of 25 micron )</td>
</tr>
</tbody>
</table>
</div>
</li>
</ul>
<p>The post <a href="https://hydraulics-bg.com/hydraulics/hydraulic-motors-ms-hydraulic/hydraulic-motors-ms-spool-valve/hydraulic-motor-mp-160-mp-200-mp-160-mp-250-mp-315-mp-400-mp-500-mp-630/">Hydraulic Motor MP 25, MP 32, MP 40, MP 50, MP 100, MP 125, MP 160, MP 200, MP 160, MP 250, MP 315, MP 400, MP 500, MP 630</a> appeared first on <a href="https://hydraulics-bg.com">Hydraulics BG</a>.</p>
]]></content:encoded>
					
		
		