<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Vannes sectionnelles à commande manuelle PC70 PC100 Archives - Hydraulics BG</title>
	<atom:link href="https://hydraulics-bg.com/fr/hydraulic/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/feed/" rel="self" type="application/rss+xml" />
	<link>https://hydraulics-bg.com/fr/hydraulic/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/</link>
	<description></description>
	<lastBuildDate>Fri, 01 Sep 2023 06:35:05 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://hydraulics-bg.com/wp-content/uploads/2023/05/favicon-100x100.png</url>
	<title>Vannes sectionnelles à commande manuelle PC70 PC100 Archives - Hydraulics BG</title>
	<link>https://hydraulics-bg.com/fr/hydraulic/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Vannes hydrauliques à commande directionnelle – Type PC100</title>
		<link>https://hydraulics-bg.com/fr/hydraulics/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/type-pc100/</link>
		
		<dc:creator><![CDATA[lenabg]]></dc:creator>
		<pubDate>Tue, 23 May 2023 11:26:27 +0000</pubDate>
				<guid isPermaLink="false">https://hydraulics-bg.com/hydraulics/non%20classé/vannes-hydrauliques-a-commande-directionnelle-type-pc100/</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td colspan="2"><span style="font-weight: 400">Paramètres techniques:</span></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td><span style="font-weight: 400">Modification / Sections</span></td>
<td><span style="font-weight: 400">jusqu’à 8</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Débit nominal</span></td>
<td><span style="font-weight: 400">80 l/min</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Débit maximal</span></td>
<td><span style="font-weight: 400">100 l/min</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Pression de service maximale, P=250; T=50 bar</span></td>
<td><span style="font-weight: 400">A , B = 300 bar</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Course de bobine</span></td>
<td><span style="font-weight: 400">+/- 7 mm</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Force d’actionnement</span></td>
<td><span style="font-weight: 400">&#60; 200 N</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Température ambiante</span></td>
<td><span style="font-weight: 400">-40C...+60C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Huile hydraulique liquide - à base d’huile minérale / huile hydraulique</span></td>
<td></td>
</tr>
<tr>
<td><span style="font-weight: 400">Viscosité</span></td>
<td><span style="font-weight: 400">12 ...800 mm2/s</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Températur fluide</span></td>
<td><span style="font-weight: 400">-15C...+80C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Fuite</span></td>
<td><span style="font-weight: 400">18cm3/min à 120bar</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://hydraulics-bg.com/fr/hydraulics/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/type-pc100/">Vannes hydrauliques à commande directionnelle – Type PC100</a> appeared first on <a href="https://hydraulics-bg.com/fr/">Hydraulics BG</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-9112 size-full" src="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc100-schema-2.png" alt="" width="431" height="510" srcset="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc100-schema-2.png 431w, https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc100-schema-2-254x300.png 254w" sizes="(max-width: 431px) 100vw, 431px" /><img decoding="async" class="alignnone wp-image-9111 size-full" src="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc100-schema-1.png" alt="" width="339" height="672" srcset="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc100-schema-1.png 339w, https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc100-schema-1-151x300.png 151w" sizes="(max-width: 339px) 100vw, 339px" /></p>
<p>The post <a href="https://hydraulics-bg.com/fr/hydraulics/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/type-pc100/">Vannes hydrauliques à commande directionnelle – Type PC100</a> appeared first on <a href="https://hydraulics-bg.com/fr/">Hydraulics BG</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Vannes hydrauliques à commande directionnelle &#8211; Type PC70</title>
		<link>https://hydraulics-bg.com/fr/hydraulics/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/type-pc70/</link>
		
		<dc:creator><![CDATA[lenabg]]></dc:creator>
		<pubDate>Tue, 23 May 2023 11:26:14 +0000</pubDate>
				<guid isPermaLink="false">https://hydraulics-bg.com/hydraulics/non%20classé/vannes-hydrauliques-a-commande-directionnelle-type-pc70/</guid>

					<description><![CDATA[<table>
<tbody>
<tr>
<td colspan="2"><span style="font-weight: 400">Paramètres techniques:</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Modification / Sections</span></td>
<td><span style="font-weight: 400">jusqu’à 8</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Débit nominal</span></td>
<td><span style="font-weight: 400">70 l/min</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Pression de service maximale, P=250; T=50 bar</span></td>
<td><span style="font-weight: 400">A , B = 300 bar</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Course de bobine</span></td>
<td><span style="font-weight: 400">+/- 7 mm</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Force d’actionnement</span></td>
<td><span style="font-weight: 400">&#60; 200 N</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Température ambiante</span></td>
<td><span style="font-weight: 400">-40C...+60C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Huile hydraulique liquide - à base d’huile minérale / huile hydraulique</span></td>
<td></td>
</tr>
<tr>
<td><span style="font-weight: 400">Viscosité</span></td>
<td><span style="font-weight: 400">12 ...800 mm2/s</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Températur fluide</span></td>
<td><span style="font-weight: 400">-15C...+80C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400">Fuite</span></td>
<td><span style="font-weight: 400">18cm3/min à 120bar</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://hydraulics-bg.com/fr/hydraulics/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/type-pc70/">Vannes hydrauliques à commande directionnelle &#8211; Type PC70</a> appeared first on <a href="https://hydraulics-bg.com/fr/">Hydraulics BG</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignnone wp-image-9107 size-full" src="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc70-schema-2.png" alt="" width="357" height="605" srcset="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc70-schema-2.png 357w, https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc70-schema-2-177x300.png 177w" sizes="(max-width: 357px) 100vw, 357px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-9108 size-full" src="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc70-schema-1.png" alt="" width="357" height="828" srcset="https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc70-schema-1.png 357w, https://hydraulics-bg.com/wp-content/uploads/2023/05/directional-control-hydraulic-valves-type-pc70-schema-1-129x300.png 129w" sizes="auto, (max-width: 357px) 100vw, 357px" /></p>
<p>The post <a href="https://hydraulics-bg.com/fr/hydraulics/vannes-hydrauliques-a-commande-directionnelle-badestnost/vannes-sectionnelles-a-commande-manuelle-pc70-pc100/type-pc70/">Vannes hydrauliques à commande directionnelle &#8211; Type PC70</a> appeared first on <a href="https://hydraulics-bg.com/fr/">Hydraulics BG</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>